· Afrikaans · Alemannisch · aragonés · asturianu · azərbaycanca · Bahasa Indonesia · Bahasa Melayu · Bân-lâm-gú · Basa Jawa · Basa Sunda · Baso Minangkabau · bosanski · brezhoneg · català · čeština · corsu · dansk · Deutsch · eesti · English · español · Esperanto · estremeñu · euskara · français · Frysk · Gaeilge · Gàidhlig · galego · Hausa · hrvatski · Igbo · interlingua · Interlingue · isiXhosa · isiZulu · íslenska · italiano · Kiswahili · Kreyòl ayisyen · kréyòl gwadloupéyen · Kurdî · latviešu · Lëtzebuergesch · lietuvių · magyar · Malagasy · Malti · Nederlands · Nedersaksies · norsk bokmål · norsk nynorsk · occitan · Oromoo · oʻzbekcha/ўзбекча · Plattdüütsch · polski · português · română · shqip · slovenčina · slovenščina · Soomaaliga · suomi · svenska · Tagalog · Tiếng Việt · Türkçe · Vahcuengh · vèneto · Wolof · Yorùbá · Zazaki · српски / srpski · беларуская · български · қазақша · македонски · монгол · русский · тоҷикӣ · українська · Ελληνικά · Հայերեն · ქართული · नेपाली · मराठी · हिन्दी · भोजपुरी · অসমীয়া · বাংলা · ਪੰਜਾਬੀ · ગુજરાતી · ଓଡ଼ିଆ · தமிழ் · తెలుగు · ಕನ್ನಡ · മലയാളം · සිංහල · བོད་ཡིག · ไทย · မြန်မာဘာသာ · ລາວ · ភាសាខ្មែរ · ⵜⴰⵎⴰⵣⵉⵖⵜ ⵜⴰⵏⴰⵡⴰⵢⵜ‎ · አማርኛ · 한국어 · 日本語 · 中文(简体)‎ · 中文(繁體)‎ · 吴语 · 粵語 · ייִדיש · עברית · اردو · العربية · پښتو · سنڌي · فارسی · ދިވެހިބަސް
その他の言語このウィキの翻訳を支援してください
Public-images-osm logo.svg power = transformer
Trafostation Alter Hellweg IMGP4722.jpg
説明
変圧器。2組の巻線間の誘導によって電圧を変換する静的な機器。大きい変圧器は普通変電所にある
適用できる要素
ノードに使用可能ウェイに使用不可能領域に使用不可能リレーションに使用不可能
よく併用されるタグ
ウィキデータ
Wikidata-logo.svgSearch Wikidata日本語の翻訳にご協力ください!
状態: 承認Page for proposal

変圧器は電力をある電圧からほかの電圧に変換する機器です。変圧器はふつう、変電所 power=substation の中にあります。

技術的な定義

A power transformer is a static piece of apparatus with two or more windings which, by electromagnetic induction, transforms a system of alternating voltage and current into another system of voltage and current for the purpose of transmitting electrical power [1]

マッピング方法

変圧器ノード としてマッピングします。変圧器はふつう変電所内にあるので、 power=substation とタグ付けされたエリアの中にノードとしてタグ付けしてください。

電柱の上にある変圧器は、 power=pole として電柱をタグ付けし、 transformer=distribution タグ(または transformer=yes)を追加することが提案されています(以下参照)。

高度なマッピング

変圧器についての詳細は、以下のようなタグ付け方法で追加することができます。一部はマッパーが電力システムに関する知識を持つ必要があります。

タグ付け

キー コメント 推奨
power transformer このノードを変圧器と定義します。 必須
transformer <用途または種類> 変圧器の用途または種類(有効な値は以下を参照)。このタグは「標準的な」変圧器の多くには必要ありません。 任意
location <場所> 変圧器の場所。有効な値は以下を参照してください。変圧器の場所が変電所の場所と同じ場合は、このタグは任意です。 推奨
voltage <高圧>;<低圧> この変圧器の2つ(またはそれ以上)の電圧。高い方が先で、低い方が後。郊外の 20kV/400V の変圧器は 20000;400、高圧の 225kV/400kV の変圧器は 400000;225000 です。3巻線変圧器は、もし2つの電圧が等しくても、3つの電圧を並べてください。 推奨
frequency <周波数> 変圧器の周波数。周波数が一般的な送電網と異なる場合は推奨。例えば、ドイツの鉄道動力網の電圧は 16.7Hz です。 任意
phases 1, 3, .. 相の数。単相の変圧器の場合は推奨。既定値は3です。 任意
rating <定格電力> kVA/MVA 変圧器の定格出力。値は kVA (キロボルトアンペア)または MVA (メガボルトアンペア)単位です。 任意

transformer の値

transformer=* が取りうる値の一覧です。
キー コメント
transformer distribution A distribution transformer transfers power from the distribution system to directly connected electricity consumers. Thus the output voltage is that of the low voltage grid in that region. For example 400/230 volt in Europe or 240/120 volt in the US. If the secondary voltage is above 1 kV it is not a distribution transformer. Note for pole mounted distribution transformers you should use this tag together with power=pole (thus no explicit power=transformer tag).
generator A generator unit transformer connects directly to the generator terminals and is used for stepping up the generator voltage to that of the transmission grid. It is almost always located physically close to the generator, typically directly outside the generator building. Unless the generator terminal voltage is known it is sufficient to tag only the secondary voltage.
converter A converter transformer is a special transformer used in HVDC converter plants. It is always located directly adjacent to the valve hall. If the voltage of the valve side is unknown it is sufficient to tag the AC switchgear side voltage.
traction A traction transformer feeds railway overhead contact lines. It is usually a single-phase transformer whose secondary voltage is that of the contact line, typically 15 kV or 25 kV.
auto An autotransformer is a transformer in which part of the winding is common to both primary and secondary circuits. Sometimes used at modest voltage ratios between the primary and secondary, such as 400000/275000 volt.
phase_angle_regulator A phase angle regulator is a special transformer for controlling the flow of power in a three-phase network by shifting the phase angle.
yes This generic value may be used to tag a transformer attached to another power feature such as a power pole (since power=transformer cannot be tagged in such cases). It is however recommended to specify the type of transformer (such as distribution) also in this case but mappers not familiar with the different flavours of transformers may use the value yes.

transformer 属性がない場合は、変圧器が上記のカテゴリのいずれにも当てはまらないことを表します。

location の値

location=* が取りうる値の一覧です。
キー コメント
location outdoor 屋外にある変圧器。変圧器が(部分的に)保護壁に囲まれていてもこの値を使用してください。この値が既定です。
indoor 建物内にある変圧器。
underground 地下にある変圧器。
rooftop 他の用途で使われている建物の屋上にある変圧器。
kiosk 小さい、ふつうは既成の建造物で、「建物」というには小さすぎるものの中にある変圧器。しかし、このようなキオスクは power=substation でタグ付けし、 substation=minor_distribution および location=kiosk 属性を追加してください。

写真 タグ付け メモ
380/110 kV Trafo, Kriegenbrunn
ノードpower=transformer
voltage=380000;110000
巨大な屋外の変圧器
Pole mounted transformer, Denmark
ノードpower=pole
transformer=distribution
voltage=10000;400
電柱上にある典型的な 10kV の変圧器。