JA:Key:wires

From OpenStreetMap Wiki
Jump to: navigation, search
利用できる言語 — Key:wires
· Afrikaans · Alemannisch · aragonés · asturianu · azərbaycanca · Bahasa Indonesia · Bahasa Melayu · Bân-lâm-gú · Basa Jawa · Basa Sunda · Baso Minangkabau · bosanski · brezhoneg · català · čeština · corsu · dansk · Deutsch · eesti · English · español · Esperanto · estremeñu · euskara · français · Frysk · Gaeilge · Gàidhlig · galego · Hausa · hrvatski · Igbo · interlingua · Interlingue · isiXhosa · isiZulu · íslenska · italiano · Kiswahili · Kreyòl ayisyen · kréyòl gwadloupéyen · Kurdî · latviešu · Lëtzebuergesch · lietuvių · magyar · Malagasy · Malti · Nederlands · Nedersaksies · norsk bokmål · norsk nynorsk · occitan · Oromoo · oʻzbekcha/ўзбекча · Plattdüütsch · polski · português · română · shqip · slovenčina · slovenščina · Soomaaliga · suomi · svenska · Tiếng Việt · Türkçe · Vahcuengh · vèneto · Wolof · Yorùbá · Zazaki · српски / srpski · беларуская · български · қазақша · македонски · монгол · русский · тоҷикӣ · українська · Ελληνικά · Հայերեն · ქართული · नेपाली · मराठी · हिन्दी · भोजपुरी · অসমীয়া · বাংলা · ਪੰਜਾਬੀ · ગુજરાતી · ଓଡ଼ିଆ · தமிழ் · తెలుగు · ಕನ್ನಡ · മലയാളം · සිංහල · བོད་ཡིག · ไทย · မြန်မာဘာသာ · ລາວ · ភាសាខ្មែរ · ⵜⴰⵎⴰⵣⵉⵖⵜ ⵜⴰⵏⴰⵡⴰⵢⵜ‎ · አማርኛ · 한국어 · 日本語 · 中文(简体)‎ · 中文(繁體)‎ · 吴语 · 粵語 · ייִדיש · עברית · اردو · العربية · پښتو · سنڌي · فارسی · ދިވެހިބަސް
その他の言語このウィキの翻訳を支援してください
Public-images-osm logo.svg wires
Power-cable.jpg
説明
送電線の線数。 "single" (1), "double" (2), "triple" (3) or "quad" (4)。
グループ: 電力
適用できる要素
ノードに使用不可能ウェイに使用可能領域に使用不可能use on relations unspecified
よく併用されるタグ
状態: 未定義

架空電力線の電力線(より正確には conductor bundle)あたりの電線(より正確には sub-conductors)の数を記述するために使います。

背景

高圧送電線には、スペーサーで区切られた2本以上の電線(sub-conductors、ワイヤー)から成る多導体(conductor bundles、ケーブル)がよく使われています。これには2つの目的があります。

  • コロナ放電を減少させること。強い電界が、電線の周囲の空気をイオン化させることがあります。これは著しい電力のロスや可聴音のノイズを発生させることがあり、このようなコロナ放電を抑えることは重要です。電界は電線の有効な直径を大きくすることで抑えることができます。多導体は、およそその直径と同じだけの直径を持つ単一の電線と同じ効果があります。
  • Mitigation of skin effect. AC current tend to flow at the surface of conductors. At 50 Hz the current cannot penetrate more than approximately 1 cm into the conductor. It is therefore inefficient to increase the diameter of thick conductors to reduce the electric resistance. A better way to increase the current capacity is to use bundled conductors. A conductor bundle having multiple thin sub-conductors will have a lower resistance than a single solid conductor having an equivalent cross section.

Conductor bundles are normally used at voltages above 200 kilovolt to limit corona losses but may also be used at lower voltages to increase the current capacity of the line.

Values

Possible values are:

  • One wire (no bundle): wires=single
  • Two wires: wires=double
  • Tree wires: wires=triple
  • Four wires: wires=quad

Other values are created by appending the phrase 'fold' after the numeral:

  • Five wires: wires=fivefold
  • Eight wires: wires=eightfold

Example

The photo on the right shows an example of wires=double. You see three cables each with two wires.

count Picture tag
1 JP Power Wires Single.JPG wires=single
2 JP Power Wires Double.JPG wires=double
3 JP Power Wires Triple.JPG wires=triple
4 JP Power Wires Quad.JPG wires=quad
5 JP Power Wires Fivefold.JPG wires=fivefold
6 JP Power Wires Hex.JPG wires=sixfold
8 JP Power Wires Octal.JPG wires=eightfold

その他のキー

線のケーブルの数は cables=* でタグ付けします(ここでは接地線を数えません)。ワイヤ数とケーブル数を特定するには、以下の単純なルールを使用してください。

  • ワイヤは他の線と絶縁されていませんが、鉄塔との間では絶縁されています。
  • ケーブルは互いに絶縁され、鉄塔との間でも絶縁されています。
  • 接地線は鉄塔との間で絶縁されていません。

A note on terminology

The names of the keys wires=* and cables=* may have been chosen a little bit unfortunate. The more common term for "wire" is sub-conductor (IEV ref 466-10-21) of a conductor bundle (IEV ref 466-10-20). A single conductor (IEV ref 466-10-19) corresponds to wires=single. Similarly twin bundle, triple bundle and quad bundle correspond to wires=double, wires=triple and wires=quad, respectively. See also Wikipedia on conductors.