Tag:electrified=contact_line
Jump to navigation
Jump to search
![]() |
![]() |
Description |
---|
An overhead line. ![]() |
Group: railways |
Used on these elements |
Useful combination |
|
Status: de facto |
Tools for this tag |
|
Specifies that a railway is electrified via wires (or rails, particularly in tunnels) situated overhead, above the tracks.
How to map
If a railway has overhead lines, add electrified=contact_line
to the way tagged with railway=*
.
specification of the type of the contact line
Key | Value | Description | Photos |
---|---|---|---|
electrified:contact_line |
trolley-type |
simple, so called trolley-type contact wire without a continuous catenary wire, just the contact wire | ![]() |
catenary |
overhead contact lines with catenary suspension, consisting of one (or two) supporting catenary wires located above the contact wire(s) | ||
rail |
overhead conductor rail installation (soffit conductor rail or conductor rail with clipped-in contact wire) | ![]() |
details for catenary overhead contact lines
In the case of a catenary system, there are different types and characteristics of catenaries that can be mapped by the following tagging:
Key | Value | Description | Photos |
---|---|---|---|
catenary |
simple |
simple catenary system with messenger wire and contact wire connected with dropper wires | ![]() |
stiched |
catenary systems that consist in comparison to the "simple" system described above of additional Y-wires at catenary masts | ![]() | |
compound |
catenary systems that consist in comparison to the "stitched" system described above of additional auxiliary messenger wire | ![]() | |
catenary:muffled |
yes |
if the catenary has dampers |
Also at catenaries there is usually one contact wire and one catenary wire in the catenary system. However, there are also designs in which there are two contact wires or two catenary wires. Please note that it is not intended to map , catenary:contact_wire=single
or catenary:auxiliary_wire=single
as the value catenary:messenger_wire=single
single
is assumed by default.
Key | Value | Description | Photo |
---|---|---|---|
catenary:contact_wire |
double |
added, if the catenary system has a doubled contact wire | ![]() |
catenary:auxiliary_wire |
double |
added, if the catenary system has a doubled auxiliary messenger wire | I've never heared about that, but we are prepared of that |
catenary:messenger_wire |
double |
added, if the catenary system has a doubled messenger wire |
Useful combinations
electrified=contact_line
cables=*
- count of overhead wires, default value 1, but there exist a few railways with morefrequency=*
- frequency in Hzvoltage=*
- voltage in V
Example
-
cables=2
Photo | Tagging |
---|---|