Afrikaans Alemannisch aragonés asturianu azərbaycanca Bahasa Indonesia Bahasa Melayu Bân-lâm-gú Basa Jawa Baso Minangkabau bosanski brezhoneg català čeština dansk Deutsch eesti English español Esperanto estremeñu euskara français Frysk Gaeilge Gàidhlig galego Hausa hrvatski Igbo interlingua Interlingue isiXhosa isiZulu íslenska italiano Kiswahili Kreyòl ayisyen kréyòl gwadloupéyen kurdî latviešu Lëtzebuergesch lietuvių magyar Malagasy Malti Nederlands Nedersaksies norsk norsk nynorsk occitan Oromoo oʻzbekcha/ўзбекча Plattdüütsch polski português português do Brasil română shqip slovenčina slovenščina Soomaaliga suomi svenska Tiếng Việt Türkçe Vahcuengh vèneto Wolof Yorùbá Zazaki српски / srpski беларуская български қазақша македонски монгол русский тоҷикӣ українська Ελληνικά Հայերեն ქართული नेपाली मराठी हिन्दी অসমীয়া বাংলা ਪੰਜਾਬੀ ગુજરાતી ଓଡ଼ିଆ தமிழ் తెలుగు ಕನ್ನಡ മലയാളം සිංහල ไทย မြန်မာဘာသာ ລາວ ភាសាខ្មែរ ⵜⴰⵎⴰⵣⵉⵖⵜ አማርኛ 한국어 日本語 中文(简体)‎ 吴语 粵語 中文(繁體)‎ ייִדיש עברית اردو العربية پښتو سنڌي فارسی ދިވެހިބަސް
Public-images-osm logo.svg cables
Power-tower.JPG
Gruppo: Power
Applicabile agli elementi
use on nodes unspecifieduse on ways unspecifieduse on areas unspecifieduse on relations unspecified
Combinazioni utili
Wikidata
Stato: non specificato

Questo tag può essere utilizzato per indicare il numero di conduttori di potenza elettricamente separati (cables nella terminologia di OSM) nelle linee elettriche (power=line) o nelle condutture (power=cable). La rete elettrica di distribuzione e trasformazione utilizza tre fasi in corrente alternata (AC), quindi ogni linea elettrica consiste in tre conduttori. Nota a volte:

  • Alcuni circuiti usano uo o due conduttori, ad esempio:
    • high voltage direct current (HVDC) transmission links,
    • single-phase or split-phase AC circuits for:
      • single wire earth return (SWER) medium voltage lines sometimes used in rural areas,
      • supply to electric railroads (e.g., German traction power network),
      • street lighting,
      • small end customers (such as individual households).
    • terminal branches of the 3-phase distribution grid that carry only 2 of the phases for an immediate connection to a small set of end customers.
  • Multiple independent circuits can share the same towers/poles. You may use multiple semicolon-separated values grouped by voltage (for example cables=6;3 for a line having two circuits of the first voltage and one circuit of the second voltage). See also circuits=*.
  • Ogni conduttore si può dividere in più sub-conduttori (wires nella terminologia OSM) that are close to each other and electrically connected (this is done to reduce corona losses at high voltages and to increase the AC current carrying capacity of the conductor, as AC current tends to run best near the surface of each wire). Vedi wires=*.
  • Non includere cavi che non portano potenza, come:
    • protective ground cables (also called earth wires),
    • passive loop cables (to reduce the magnetic field)
    • telefono o altri cavi di comunicazione,
    • guy wires (for mechanical support).

Vedi anche

  • Key:circuits Numero di circuiti elettrici della linea di alimentazione o di collegamento via cavo.

Una nota sulla terminologia

I nomi delle chiavi wires=* e cables=* sono stati una scelta non proprio felice. Il termine migliore per "cable" e conductor che può essere un single conductor (IEV ref 466-10-19) corrisponde a wires=single o un conductor bundle (IEV ref 466-10-20) corrisponde a wires=double,triple,...