IT:Key:wires

From OpenStreetMap Wiki
Jump to: navigation, search
Lingue disponibili — Key:wires
Afrikaans Alemannisch aragonés asturianu azərbaycanca Bahasa Indonesia Bahasa Melayu Bân-lâm-gú Basa Jawa Baso Minangkabau bosanski brezhoneg català čeština dansk Deutsch eesti English español Esperanto estremeñu euskara français Frysk Gaeilge Gàidhlig galego Hausa hrvatski Igbo interlingua Interlingue isiXhosa isiZulu íslenska italiano Kiswahili Kreyòl ayisyen kréyòl gwadloupéyen kurdî latviešu Lëtzebuergesch lietuvių magyar Malagasy Malti Nederlands Nedersaksies norsk norsk nynorsk occitan Oromoo oʻzbekcha/ўзбекча Plattdüütsch polski português português do Brasil română shqip slovenčina slovenščina Soomaaliga suomi svenska Tiếng Việt Türkçe Vahcuengh vèneto Wolof Yorùbá Zazaki српски / srpski беларуская български қазақша македонски монгол русский тоҷикӣ українська Ελληνικά Հայերեն ქართული नेपाली मराठी हिन्दी অসমীয়া বাংলা ਪੰਜਾਬੀ ગુજરાતી ଓଡ଼ିଆ தமிழ் తెలుగు ಕನ್ನಡ മലയാളം සිංහල ไทย မြန်မာဘာသာ ລາວ ភាសាខ្មែរ ⵜⴰⵎⴰⵣⵉⵖⵜ አማርኛ 한국어 日本語 中文(简体)‎ 吴语 粵語 中文(繁體)‎ ייִדיש עברית اردو العربية پښتو سنڌي فارسی ދިވެހިބަސް
Public-images-osm logo.svg wires
Power-cable.jpg
Descrizione
Numero di fili per cavo di alimentazione. "single" (1), "double" (2), "triple" (3) or "quad" (4).
Gruppo: Power
Applicabile agli elementi
should not be used on nodesmay be used on waysshould not be used on areasuse on relations unspecified
Combinazioni utili
Wikidata
Stato: non specificato

Per descrivere il numero di fili (o meglio: sub-conduttore) per cavo di alimentazione (o meglio: fascio di conduttori) di una linea elettrica aerea.

Storia

Le linee di trasmissione ad alta tensione spesso utilizzano fasci di conduttori (cavi) ciascuna da due o più singoli sub-conduttori (fili) separate da distanziatori. Questo ha due scopi principali:

  • Reduction of corona discharges. The strong electric field around a conductor can cause ionisation of the surrounding air. This may result in signicant power losses and audible noise and it is therefore important to limit such coronal discharges. The electric field can be reduced by increasing the effective diameter of the conductor. A conductor bundle will behave similarly to a single conductor having a diameter roughly corresponding to the diameter of the bundle.
  • Mitigation of skin effect. AC current tend to flow at the surface of conductors. At 50 Hz the current cannot penetrate more than approximately 1 cm into the conductor. It is therefore inefficient to increase the diameter of thick conductors to reduce the electric resistance. A better way to increase the current capacity is to use bundled conductors. A conductor bundle having multiple thin sub-conductors will have a lower resistance than a single solid conductor having an equivalent cross section.

Conductor bundles are normally used at voltages above 200 kilovolt to limit corona losses but may also be used at lower voltages to increase the current capacity of the line.

Valori

Possibili valori sono:

  • Un filo (no fascio): wires=single

Altri valori sono creati aggiungendo la parola 'fold' dopo il numero:

  • Cinque fili: wires=fivefold
  • Otto fili: wires=eightfold

Esempi

La foto sulla destra mostra un esempio di due fili wires=double. Vedi tre cavi ognuno di due fili.

count Figura tag
1 JP Power Wires Single.JPG wires=single
2 JP Power Wires Double.JPG wires=double
3 JP Power Wires Triple.JPG wires=triple
4 JP Power Wires Quad.JPG wires=quad
5 JP Power Wires Fivefold.JPG wires=fivefold
6 JP Power Wires Hex.JPG wires=sixfold
8 JP Power Wires Octal.JPG wires=eightfold

Altri valori associabili

Il numero di cavi della linea è taggato con cables=* (qui gli scaricatori non contano). Per distinguere cavi dai fili usa la semplice regola:

  • Fili non sono isolati tra di loro, ma isolati dal pilone.
  • Cavi sono isolati tra di loro e dal pilone.
  • Gli scaricatori non sono isolati dal pilone

Una nota sulla terminologia

I nomi delle chiavi wires=* ecables=* sono stati una scelta un po' sfortunata. Il miglior termine per "filo" è sub-conductor (IEV ref 466-10-21) di un conductor bundle (IEV ref 466-10-20). Un conduttore singolo (IEV ref 466-10-19) corrisponde a wires=single. Lo stesso vale per twin bundle, triple bundle e quad bundle che corrispondono a wires=double, wires=triple e wires=quad, rispettivamente. Vedi anche Wikipedia on conductors.